Moving Flow Meter Calibration On-Site

by | Apr 13, 2016 | Measurement Instrumentation

Jim Cahill

Jim Cahill

Chief Blogger, Social Marketing Leader


At the Emerson Exchange Brussels conference, Emerson’s Jerome Desmoulieres co-presented with TEREOS, Flow Calibration On Site: How to maximize your turnaround. Their abstract:

Turnarounds are more and more time limited. But production and quality departments’ requests remain for calibration and certification. TEREOS and NESTLE, in North of France, worked with Emerson to find a solution. Job was done on their plant, thanks to a Flow Calibration Mobile Bench. Both companies saved money and time, eliminate risks, get flexibility in turnaround management and deliver expected certificates on time to their production and quality departments.

The site is located in the north of France in regions where sugar beets grow. The plant is a site where pilots are performed in search of innovations in the manufacturing process. 20,000 tons of beets are processed each day with sugar and alcohol produced. A distillation unit converts some of the sugar into alcohol.

One of the issues the plant experienced was in the distillation unit was variability in production levels. Another was in the quality parameters in the alcohol produced. Calibration of the flow measurement devices was a long process. The flow meters were taken out of the line, trucked to the supplier bench off site and then returned to the site for reinstallation.

On-Site-CalibrationThe solution was to bring the calibration bench to the plant to do all the calibration on site. This provided more flexibility, calibration and less risk. The biggest benefit was the reduced time involved to give time for other turnaround activities.

The flow mobile bench supported calibration of several types of flowmeter technologies including Coriolis, vortex, magmeters and other. Water was used as the flow medium, which had a constant density to provides e flow and mass calibration.

As part of the solution, reports and certificates were provided including “as-found” and “as-left” calibration. As measurement were performed, decisions could be made to recalibrate or not if a meter was in range, but could be better. This type of flexibility was not possible with the old method of an external calibration bench.

They summed up the presentation noting the benefits of reduced delay and avoiding potential damage shipping flowmeters to and from the external calibration site. The operations staff had more flexibility. Bench performance and stability are very good. The certificates created are detailed, professional and met the needs of the plant. One lesson learned is that they would like to have an enlarged flow range.

The master meters were owned and provided as a service by Emerson as part of the mobile bench.

For more news and updates from the Emerson Exchange Brussels conference, visit the Brussels 2016 group in the Emerson Exchange 365 community.

Popular Posts

Comments

Follow Us

We invite you to follow us on Facebook, LinkedIn, Twitter and YouTube to stay up to date on the latest news, events and innovations that will help you face and solve your toughest challenges.

Do you want to reuse or translate content?

Just post a link to the entry and send us a quick note so we can share your work. Thank you very much.

Our Global Community

Emerson Exchange 365

The opinions expressed here are the personal opinions of the authors. Content published here is not read or approved by Emerson before it is posted and does not necessarily represent the views and opinions of Emerson.

PHP Code Snippets Powered By : XYZScripts.com