Here’s a brief 1:40 YouTube video, Treating control valve noise with Fisher Whisper technology, that shares how the bar continues to be raised for control valve noise reduction by reducing sound pressure levels to a manageable level with Fisher Whisper technology. More innovations to come!
Posts by or with Grady Emswiler
Cutting Control Valve Noise
The modal attenuator consists of a series of carefully engineered resonant cavities to provide sound reduction across a wide spectrum of frequencies. The full-bore design allows unrestricted flow, and internal drain channels drain off condensate which could build up in the device and reduce performance. Installed just downstream of the valve, the modal attenuator achieves an overall sound reduction up to 15 dBa, while creating no restriction in flow capacity whatsoever. The device can be used on existing valves or paired with a low noise control valve to achieve even higher levels of noise reduction. Unlike diffusers or silencers, the modal attenuator works consistently across a wide range of flow rates.