Closing Refinery Measurement Gaps Without Shutdowns

by , | Nov 9, 2026 | Downstream Hydrocarbons, Measurement Instrumentation | 0 comments

Refiners rarely lack ideas for new measurement points. The challenge is justifying a measurement that requires a shutdown, a pipe cut, or a new process penetration. Emerson’s Marcelo Carugo, Senior Director, Global Refining Market Strategy, explains how non-intrusive instrumentation changes that equation in an interview on Hydrocarbon Processing’s The Main Column podcast.

Why It Matters

Flexim FLUXUS non-intrusive flow meter

Refineries are pushing outages out as far as possible, so improvements that need a process penetration often wait on a wish list until the next turnaround. Every new penetration can add installation complexity, safety reviews, a potential leak path, and future maintenance requirements. Non-intrusive measurement gathers process or asset information through or from outside the containment boundary, allowing teams to add measurements without cutting into the process. This gives engineers a practical way to improve visibility and support safety, reliability, and operational decisions between turnarounds.

Key Takeaways

  • Measurement gaps persist because new points often require an outage windows, permits, engineering reviews, and work in harsh or congested areas.
  • Non-intrusive instruments measure through or from outside the pipe or vessel wall, avoiding new process penetrations.
  • High-value applications are often tied to safety risk, availability risk, recurring maintenance burden, or process uncertainty.
  • Continuous integrity monitoring shifts corrosion and erosion assessment from periodic snapshots to trends.
  • Start small with a few high-value points tied to measurable outcomes, then scale with standardized practices and clear data governance.
What is non-intrusive measurement in a refinery?

Non-intrusive measurement gets process or asset information without creating a new penetration into a pipe, vessel, or process boundary. Instead of inserting an instrument into the process, the reading is taken through or from outside the containment boundary. That lets refinery teams add data points without cutting a pipe, avoiding the added installation complexity, safety reviews, potential leak paths, and future maintenance that a new penetration brings.

How can I add measurement points in a refinery without a shutdown?

Use non-intrusive instruments that measure through or from outside the pipe or vessel wall. Because they require no new process penetration, they avoid the shutdown and pipe cut that often defer new measurement points until the next turnaround. Start with a small set of high-value points tied to measurable outcomes, demonstrate the value, then scale with standardized practices and clear governance on how the data will be used.

Which refinery applications benefit most from non-intrusive instrumentation?

The strongest opportunities are where a measurement gap ties to safety risk, availability risk, recurring maintenance, or process uncertainty. Examples include asset integrity monitoring, such as wall thickness; heat exchanger performance; harsh-service flow in cokers, fluid catalytic cracking (FCC) units, vacuum unit bottoms, and hydrocrackers; utilities and tank farms; and pressure relief valve monitoring for emissions compliance. Start where better data would change when you intervene, inspect, or clean.

What is an alternative to thermowells for temperature measurement in erosive service?

Adding or modifying a thermowell can be difficult, and erosive or high-velocity fluids can wear thermowells away. Non-intrusive temperature measurement, such as Emerson’s Rosemount™ X-well™ technology, takes the reading without a process penetration. It supports troubleshooting, heat transfer monitoring, energy balance, and reliability by improving confidence in the data behind operational decisions.

Why Measurement Gaps Persist

The question is rarely whether a another measurement would be useful. The challenge is whether the measurement can be justified when installation requires a shutdown, pipe cutting, engineering reviews, permits, or installation in harsh or congested areas. Because many refinery units operate continuously and outage windows are limited, these improvements get deferred until a turnaround.

In practical terms, non-intrusive measurement means obtaining useful process or asset information without creating a new penetration into a pipe, vessel, or process boundary. Instead of inserting an instrument into the process, the measurement is taken through or from outside the containment boundary.

Where Non-Intrusive Measurement Creates the Most Value

According to Marcelo, the strongest opportunities are where a measurement gap links to safety risk, availability risk, recurring maintenance, or process uncertainty. Examples include:

  • Asset integrity monitoring, such as wall thickness measurement
  • Heat exchanger performance
  • Harsh-service flows with particulates in cokers and fluid catalytic cracking (FCC) units, vacuum unit bottoms, and hydrocrackers
  • Utilities and tank farms

He advised starting where better data would change a decision about when to intervene, inspect, clean, or reduce risk. Flexim Clamp-on Ultrasonic Flow Meters are ideal for measuring the harsh-service flow applications.

For asset integrity, traditional inspections remain valuable but are periodic snapshots. In harsh, changing conditions, it can be hard to see how corrosion or erosion evolves between inspections. Non-intrusive monitoring at high-risk points shifts the conversation to trends, showing whether degradation rates are changing and whether process conditions are contributing.

Temperature presents another opportunity. Adding or modifying a thermowell can be difficult, while erosive or high-velocity fluids can wear thermowells over time. Marcelo highlighted Emerson’s non-intrusive Rosemount™ X-well™ technology as another option that can support troubleshooting, heat transfer monitoring, energy balance, and reliability by improving confidence in the data behind operational decisions.

Deciding Where to Start and How to Scale

Marcelo recommended starting with the operational problem: areas with recurring uncertainty, recurring maintenance issues, or safety concerns. Emissions compliance is one such area. Monitoring pressure relief valves (PRVs) that open and release fluid to the environment, or that close but keep fluctuating, is an important application for non-intrusive instrumentation.

Identify a small set of high-value measurement opportunities tied to measurable outcomes. Once value is demonstrated, scale the approach with standardized practices and clear governance on how the data will be used.

He also pointed to digital programs. Artificial intelligence (AI) models, agents, and machine learning all need trustworthy inputs. If important process or asset conditions go unmeasured, the digital layer has blind spots. Non-intrusive measurement helps fill those gaps where traditional measurement was previously hard to justify.

Learn More

Listen to Marcelo Carugo discuss how refiners can close measurement gaps with less disruption on Hydrocarbon Processing’s The Main Column podcast. Then explore Emerson’s non-intrusive measurement solutions for improving visibility into difficult-to-measure refinery applications.

Comments

Author

Featured Emerson Expert

Follow Us

We invite you to follow us on Facebook, LinkedIn, Twitter and YouTube to stay up to date on the latest news, events and innovations that will help you face and solve your toughest challenges.

Do you want to reuse or translate content?

Just post a link to the entry and send us a quick note so we can share your work. Thank you very much.

Our Global Community

Emerson Exchange 365

This blog features expert perspectives from Emerson's automation professionals on industry trends, technologies, and best practices. The information shared here is intended to inform and educate our global community of users and partners.

 

PHP Code Snippets Powered By : XYZScripts.com