Posts Tagged ‘thermal oxidizer’

Solving Thermal Oxidizer Interacting Loops

Posted in Chemical, Process Optimization, Variability Management on Tuesday, December 2nd, 2014. 3 comments so far
Tags: , , , , , , , , ,

Author: Sonal Gilani In an earlier post, Improving Energy Efficiency in Thermal Oxidizers, I highlighted how switching control loops from manual to automatic mode improved overall efficiency. Emerson’s James Beall shared a second story on this thermal oxidizer equipment, which is used to destroy the waste gases containing volatile organic compounds and hazardous air pollutants […]

Improving Energy Efficiency in Thermal Oxidizers

Posted in Chemical on Wednesday, November 12th, 2014. 2 comments so far
Tags: , , , , ,

Author: Sonal Gilani Thermal oxidizers are used to destroy the waste gases containing volatile organic compounds (VOC) and volatile hazardous air pollutants (HAP) by raising the temperature of the material above its auto ignition point in the presence of oxygen. The high temperature is maintained for sufficient time to complete combustion to carbon dioxide and […]