EDDL Archives - Page 2 of 9 - Emerson Automation Experts - Emerson Automation Experts

Posts Tagged ‘EDDL’

Managing Analyzers, Transmitters, and Control Valves with a Common Approach

Posted in Analyzers, Asset Optimization on Tuesday, May 21st, 2013. No comments yet
Tags: , , , , ,

In an earlier post, Measuring Hydrocarbon Dew Point with Gas Chromatographs, we highlighted the challenges with liquids in natural gas. Emerson’s Jonas Berge added a comment [hyperlinks added]: The 700XA gas chromatograph can be integrated into intelligent device management (IDM) software part of the asset management software and be managed just like pressure and temperature […]

Update and History of Field Device Integration (FDI) Effort

Posted in Asset Optimization, Interoperability on Friday, March 15th, 2013. No comments yet
Tags: , , , , , , , , ,

Standards are an essential part of technology advancement. They provide a way for users to choose from multiple suppliers, and suppliers to create solutions with multiple suppliers’ technologies. In areas where competing standards emerge, it’s great when a path to a unified standard emerges. Such is the case with smart instrumentation device integration. The Field […]

Adopting Smart Instrumentation Diagnostic Operator Alert Standard

Posted in Foundation Fieldbus, Interoperability on Tuesday, March 12th, 2013. One comment so far
Tags: , , , , , , , ,

The Fieldbus Foundation has been collaborating with the international process industry end-user association, NAMUR, to adopt the NAMUR NE-107 standard as part of the Fieldbus Foundation’s Diagnostics Profile Specification (FF-912). The purpose of this NE-107 standard is to make use of diagnosis from intelligent field devices to support operators to take appropriate actions as required. […]

Device Revisions Management Best Practices-Is DD the Problem or the Solution?

Posted in Asset Optimization, Emerson Exchange, Interoperability on Thursday, October 18th, 2012. No comments yet
Tags: , , , , , , , , , ,

Emerson’s Jonas Berge posed this question, which he addressed in his Emerson Exchange presentation with the same name. His abstract: Keeping the system up to date with new types and versions of 4-20 mA/HART, WirelessHART, FOUNDATION fieldbus, and PROFIBUS devices as they come into the plant over its operational life is a challenge in most […]

Integrating Gas Chromatographs with Control and Device Management

Posted in Analyzers, Foundation Fieldbus on Thursday, December 15th, 2011. 2 comments so far
Tags: , , , , , ,

Gas Chromatographs (GCs) are used in many process-manufacturing processes. Some GC applications include fuel & flare gas analysis, cracking furnace BTU firing rates, gas ratios, and a whole lot more. Wikipedia defines the gas chromatography process: …used in analytical chemistry for separating and analysing compounds that can be vaporized without decomposition. Typical uses of GC […]